![Siemens ST950 Скачать руководство пользователя страница 129](http://html.mh-extra.com/html/siemens/st950/st950_user-manual_1265504129.webp)
ST950 Plus+ User Manual
ST950 Plus+ User Manual
Page 129 of 176
667/HE/53000/000
Issue 2
Unrestricted
Use with Care!
Dim signals may be difficult for road users to see during daylight hours
6.9.14
Junction System Testing
Using the detect lights on the above ground detectors, ensure that all above ground detectors
(E.g. Kerbside, On-Crossing) are functional and have the required zone of detection.
Using the web page:
Status and Configuration → Controller → I/O → Lin
es
Or the Handset command “IOP”, check that all road detector loops
or other Above Ground
Detector, demand pushbuttons etc are correctly connected/configured.
Clear all faults in the log and allow the junction to run normally. Periodically check the fault table
/ system log and ensure that no faults are raised. Verify that the controller has the correct date
and time and is keeping correct time.