Engineer Programming Via the Keypad
84
Siemens Building Technologies
Fire Safety & Security Products
09.2008
10.17.2 Editing
To view and edit and program user rights, enter the programming menus listed
below.
To edit users on the system:
1.
Scroll to the FULL ENGINEER> USERS> EDIT programming option.
2.
Press SELECT.
3.
The following user settings are available to be edited:
–
Change Name:
edit the current user name
–
Change Type:
edit the current user type
–
User Options:
enable or disable available user options (unset, partset A,
isolate, etc.)
–
Change Areas
: enable or disable user access to areas
–
PACE:
enable or disable PACE capability
–
RF Fob:
enable or disable RF Fob access
4.
Press BACK to exit from the USER menu options.
10.17.3 Deleting
To delete users on the system:
1.
Scroll to the FULL ENGINEER> USERS> DELETE programming option.
2.
Press SELECT.
Î
A prompt is displayed, asking if the user is sure.
3.
Press YES to delete the user.
10.18 Setup SMS
To set up the SMS functionality on the system:
1.
Scroll to the FULL ENGINEER> SETUP SMS programming option.
2.
Press SELECT.
3.
The following configuration options are available:
–
Enable SMS:
toggle between the SMS ENABLED and SMS DISABLED for
preferred option
–
Phone Number:
enter phone number for SMS calls
–
Reported Events:
enable or disable SMS calls for specific events; Alarms,
Confirmed, Fault, Mode Change, Inhibit Isolate, Other Events
4.
Press BACK to exit the SMS SETUP menu.