background image

21" Gray Scale Flat Panel Display

SMD 21300

Instruction Manual

10/2003

display

SOLUTIONS

Содержание SMD21300

Страница 1: ...21 Gray Scale Flat Panel Display SMD 21300 Instruction Manual 10 2003 displaySOLUTIONS ...

Страница 2: ... 5 5 Screen saver 11 6 Adjustments 12 6 1 Overview 12 6 2 Explanations for program description VOSD 12 6 3 VOSD program description 13 6 4 Short cuts 15 7 Operation 16 7 1 Switching on the display and PC 16 7 2 Cleaning 16 7 3 Maintenance 17 8 Fault diagnostics 18 9 Technical data 19 9 1 Display 19 9 2 Power supply 19 9 3 Inputs outputs 20 9 4 Controls and connection elements 20 9 5 Mechanical des...

Страница 3: ...Dimensional drawings 23 10 1 Front view 23 10 2 View from left 24 10 3 Plan view 25 11 Remarks and contact address 26 11 1 Remarks 26 11 2 Contact address 26 2 21 gray scale flat panel display SMD 21300 A5E00185696B 001 ...

Страница 4: ... because of the use of LCD technology The flat panel display provides a flicker free picture even with low refresh rates 60 Hz The display thus fulfills even the strictest ergonomic requirements The flat panel display has a TFT display module with a very wide viewing angle The use of a monochrome panel means that a high picture brightness is possible Modification of gray scale setting The reproduc...

Страница 5: ...ger There is a danger to life if the warning information is not observed Severe personal injury or damage to property may occur Do not open the monitor yourself Certain components inside the units are at high voltage i e touching these components presents a danger to life Only use a perfect power supply cable A damaged power supply cable may result in a fire or electric shock When disconnecting th...

Страница 6: ...r supply cables with PE contact Only insert into sockets with PE contact 5 For certain applications the video earth can be connected to the PE via the additional PE connection in the plug panel observe IEC 601 1 6 Close the plug panel using the provided cover and lock with the screw Notice for users The closed terminal panel must not be opened by the user Servicing information If housing component...

Страница 7: ...ction Manual and VOSD SMD 21300 D Display with stand CD with Instruction Manual and VOSD European power cable US power cable DVI video cable Note It is recommendable to keep the packaging material for subsequent transport of the unit 6 21 gray scale flat panel display SMD 21300 A5E00185696B 001 ...

Страница 8: ... Provide adequate ventilation Ventilation holes are located on the rear of the housing Ambient temperature The ambient temperature must not fall below or exceed the permitted values Minimize reflections The unit should be positioned so that reflections of lights windows pieces of furniture with shiny surfaces or light colored walls do not appear on the screen Minimize mirroring In order to reduce ...

Страница 9: ...ng steps should be carried out in the given sequence 5 1 Connecting the power and signal cables 5 1 1 Position of connections The power supply and DVI connections are located in the connection panel at the rear of the display under a cover Caution The cover of the connection panel must only be opened for servicing While the cover is opened no patients may be present in the vicinity The cover is cl...

Страница 10: ...lay The power supply to the display is connected using an appliance plug 5 1 3 DVI connection The display has a single link DVI D connection Use the supplied cable or another high quality cable The picture quality noise immunity and radiated interference of the complete system depend on the cable quality and length 5 1 4 Connection procedure Caution The display can be tilted When handling it is po...

Страница 11: ...hannel Switching displays on before PC Switch on all displays The operation LED now lights up orange Switch on the PC The operation LED lights up green respectively flashing green and the picture is visible on the display Switching PC on before displays Switch on the PC Switch on all displays The operation LED now lights up green respectively flashing green Note If the operation LED does not light...

Страница 12: ...in TFT displays Image sticking is the effect where a faint image of the previous screen contents can still be seen after the display contents have changed By using a screen saver with permanently changing screen contents unnecessary effects of the same image are avoided 21 gray scale flat panel display SMD 21300 11 A5E00185696B 001 ...

Страница 13: ...xt file on the CD The program has two display levels user and servicing In the user level only a portion of the functions are seen which are available in the servicing level The servicing level can be selected by entering a password 6 2 Explanations for program description VOSD U user Mainly data can be read and test patterns displayed S servicing This level is only for authorized servicing person...

Страница 14: ...of displays 1 10 Input of number of connected displays Autodetect Start button Automatically searches for all connected displays The values for connection type display type serial port display number and display type are determined These data can also be set manually in the following functions Connection type Serial port DDC SDG 2125 DM DDC SDG 1612 D USB Communication via separate RS 232 cable Co...

Страница 15: ...atus U Type Read only Type of unit e g SMD 21300 Serial number Read only Serial number of display Hardware revision Read only Release version of hardware FPGA 1 revision Read only Release version of FPGA 1 FPGA 2 revision Read only Release version of FPGA 2 Firmware rev Read only Release version of firmware Active LUT Read only Number of currently selected LUT DPMS mode Read only On off mode with ...

Страница 16: ... pattern U Suppress test pattern Black background produced Hide test pattern U Suppress test pattern Standard background displayed User defined U Selection list Selection of additional test patterns in BMP format installed by servicing personnel Help U About U Read only Information on software Contents A Read Only Discription of program 6 4 Short cuts Short cuts can be used to call the following f...

Страница 17: ...ommended cleaning and disinfection agents Agent class Examples Alcohol Ethyl alcohol Hospiset cloth Mikrozid liquid Chlorine derivatives Terralin Quartamon Med Pyridine derivatives Spray Activ Guanidine derivatives Lysoformin spezial Quaternary compounds Incidur spray Standard household washing up liquid Fairy Ultra Pril Palmolive A test has been carried out with this Impermissible cleaning and di...

Страница 18: ...sonnel according to the regulations and corrected as necessary The serial luminance meter and the serial spot meter are possible as measuring instruments Both units can be directly connected to the display The adjustment can be carried out automatically using the SMfit ACT program version 3 0 or later The settings can also be carried out manually using the serial spot meter and the VOSD program 21...

Страница 19: ...down mode to save power and to spare the backlight Red continuous light Internal fault Please contact your supplier Red flashing at 1 Hz Timing outside sync area of the display Please contact your supplier Video signal detected but the display adjustment is incorrect Check adjustment via VOSD or SMfit ACT z B LUT luminance no test pattern aso No picture Green continuous light or flashing at 1 Hz V...

Страница 20: ... 1 typically 600 1 in dark environment Horizontal viewing angle Typically 170 with CR 10 1 Vertical viewing ankle Typically 170 with CR 10 1 Protective screen No Backlight PLANON blue toning Picture brightness Stabilized 400 cd m typically 700 cd m Lifetime of backlight Min 30 000 hours constant brightness at 400 cd m 9 2 Power supply Power supply connection Appliance plug Mains voltage 100 V to 2...

Страница 21: ...6 contact mini DIN socket Protected by a cover 1x power supply socket 1x DVI 1x RJ 45 1x USB type B optional Note the display is set using the VOSD or SMfit ACT software 9 5 Mechanical design Housing components Metal sectional frame Protective screen No Ventilation openings In rear panel Degree of protection front IP20 to DIN 40 050 Connection panel At rear covered Weight Without stand With stand ...

Страница 22: ...ments Operation Vibration To EN 60 068 2 6 10 to 58 Hz at 0 075 mm deflection 58 to 500 Hz at 10 m s Shock To EN 60 068 2 29 150 m s 6 ms Packed unit Vibration To EN 60 068 2 6 5 to 9 Hz at 3 5 mm deflection 9 to 500 Hz at 10 m s Shock To EN 60 068 2 29 250 m s 6 ms in storage packaging 9 8 Safety specifications Safety standards EN 60 601 1 Approvals CAN CSA C 22 2 No 601 1 and UL 2601 1 Protectio...

Страница 23: ...er supply lines EN 61 000 4 5 1 kV symmetric 2 kV unsymmetric Static discharge on casing parts ESD EN 61 000 4 2 8 kV air 6 kV contact RF irradiation EN 61 000 4 3 80 MHz 2500 MHz 3 V m 80 AM 1 kHz EN V 50 204 pulsed 895 900 903 5 MHz 10 V m 50 duty cycle Low frequency and static magnetic fields EN 61 000 4 8 30 A m Magnetic constant fields Max 4000 A m Magnetic alternating fields Max 1000 A m 22 ...

Страница 24: ...10 03 Instruction Manual 10 Dimensional drawings All dimensions in mm 10 1 Front view 21 gray scale flat panel display SMD 21300 23 A5E00185696B 001 ...

Страница 25: ...10 03 Instruction Manual 10 2 View from left 24 21 gray scale flat panel display SMD 21300 A5E00185696B 001 ...

Страница 26: ...10 03 Instruction Manual 10 3 Plan view 21 gray scale flat panel display SMD 21300 25 A5E00185696B 001 ...

Страница 27: ...of a previous or existing agreement commitment or statutory right and do not change the latter Guarantee All commitments on the part of Siemens AG are contained in the respective sales contract which also contains the complete and solely applicable warranty conditions These warranty conditions in the contract are neither extended nor limited by the contents of this Instruction Manual Further units...

Страница 28: ...Siemens AG Automation and Drives Systems Engineering Display Technologies Order No A5E00185696B 001 Siemens AG 2003 All rights reserved w w w s i e m e n s c o m d i s p l a y s ...