Scale parameters and functions
8.21 DR 22 Tolerance parameters
SIWAREX WP251
116
Manual, 12/2015, A5E37203357A
8.21.3
Tolerance limit TH2
This parameter defines the limit of the second tolerance band above the set point. The
setting conforms to the selected tolerance reference (percentage or absolute) and must be
greater than or equal to tolerance limit TH1.
8.21.4
Tolerance limit TH1
This parameter defines the limit of the first tolerance band above the set point. The setting
conforms to the selected tolerance reference (percentage or absolute) and must be less than
or equal to tolerance limit TH2.
8.21.5
Tolerance limit TL1
This parameter defines the limit of the first tolerance band below the set point. The setting
conforms to the selected tolerance reference (percentage or absolute) and must be less than
or equal to tolerance limit TL2 as a positive value.
8.21.6
Tolerance limit TL2
This parameter defines the limit of the first tolerance band below the set point. The setting
conforms to the selected tolerance reference (percentage or absolute) and must be greater
than or equal to tolerance limit TL1 as a positive value.
8.21.7
Behavior in case of TH1 error
This parameter defines the limit of the first tolerance band below the set point. The setting
conforms to the selected tolerance reference (percentage or absolute) and must be greater
than or equal to tolerance limit TL1 as a positive value.
8.21.8
Behavior in case of TL1 error
This parameter defines the limit of the first tolerance band below the set point. The setting
conforms to the selected tolerance reference (percentage or absolute) and must be greater
than or equal to tolerance limit TL1 as a positive value.
8.21.9
Pulse duration for pulse post dosing
This parameter defines how long (ms) the fine signal is switched on when post-dosing in
pulsing mode was set as the response to a TL1 violation in the tolerance check (function
code 4). The pause time of pulsing mode corresponds to the settling time before standstill 2
(DR 3).
Содержание SIWAREX WP251
Страница 28: ...Mounting 5 3 Mounting on the SIMATIC S7 1200 SIWAREX WP251 28 Manual 12 2015 A5E37203357A ...
Страница 40: ...Connection 6 12 Attachment of calibration protection plate SIWAREX WP251 40 Manual 12 2015 A5E37203357A ...
Страница 56: ...Commissioning 7 5 Service with the SIWATOOL program SIWAREX WP251 56 Manual 12 2015 A5E37203357A ...
Страница 162: ...Scale parameters and functions 8 38 DR 48 date and time 2 for Modbus SIWAREX WP251 162 Manual 12 2015 A5E37203357A ...
Страница 212: ...Technical specifications 13 3 Approvals SIWAREX WP251 212 Manual 12 2015 A5E37203357A ...
Страница 218: ...List of abbreviations B 1 List of abbreviations SIWAREX WP251 218 Manual 12 2015 A5E37203357A ...