Technical data
13.2 Electrical, EMC and climatic requirements
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
169
13.2
Electrical, EMC and climatic requirements
Electrical protection and safety requirements
Table 13- 12 Requirements: Electrical protection and safety requirements
Met requirement
Standards
Comments
Safety regulations
IEC 61010-1
IEC 61131-2; UL 508
CSA C22.2 No.142
Protection class
IEC 61140
Module is operated with protective extra-low
voltage.
The protective conductor connection serves
only a functional earth to dissipate interfer-
ence currents
IP degree of protection
IP 20 to IEC 60529
•
Protection against contact with
standard probe
•
Protection against solid bodies with
diameters in excess of 12.5mm
•
No special protection against water
Air gaps and creepage distanc-
es
IEC 60664
IEC 61131-2
IEC 61010-1
UL 508
CSA C22.2 No. 145
EN 50156-1
Overvoltage category II
Pollution degree 2
PCB material IIIa
Conductor path distance 0.5 mm
Isolation stability
IEC 61131-2
CSA C22.2, No. 142
UL508
Ethernet Port:
1 500 V AC (shield and signals)
Additional electrical circuits:
Test voltage:
500 V AC or 707 V DC
Test du
ration: ≥
1 minute
Short circuit current: ≥ 5 mA
Содержание SIWAREX WP231
Страница 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Страница 24: ...Application planning 4 2 Parameter assignment options SIWAREX WP231 24 Manual 07 2014 A5E31238908A 02 ...
Страница 108: ...Scale parameters and functions 8 15 DR 15 tare settings SIWAREX WP231 108 Manual 07 2014 A5E31238908A 02 ...
Страница 131: ...Scale parameters and functions 8 26 DR 48 date and time 2 for Modbus SIWAREX WP231 Manual 07 2014 A5E31238908A 02 131 ...
Страница 132: ......
Страница 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Страница 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Страница 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...