Mounting
5.2 Installing the compact installation unit
RN-S SA
38
Operating Instructions, 09/2016, A5E32605810A-03
5.2.8
Checking the installation
DANGER
Personal injury and damage to property
Incorrectly set countersunk head screws lead to erroneous measurements due to blocking
and can lead to the scale overflowing. Personal injury and material damage may occur.
NOTICE
Destruction of the load cells and the installation unit
Check that the load cells and installation unit are installed correctly, e.g. by checking the
mounting dimensions and oscillation distances. Incorrect assembly can lead to destruction
of the load cell and the installation unit.
1.
Check to ensure that the following items are fulfilled after the installation:
–
The load bearing implement must be able to oscillate freely.
–
The countersunk head screws
③
should be located as close as possible to the center
in the bores of the top plate
①
. This gives the top plate ideal freedom of movement
and it prevents any incidental forces from occurring.
To do this, lift the centering washer
②
against the top plate. The installation has been
carried out optimally if the centering washer rests all-over.
Figure 5-9
Lifting protection and pendulum limitation
Содержание SIWAREX WL280
Страница 8: ...Introduction 1 5 Environmental protection RN S SA 8 Operating Instructions 09 2016 A5E32605810A 03 ...
Страница 20: ...Description 3 2 Design and function RN S SA 20 Operating Instructions 09 2016 A5E32605810A 03 ...
Страница 44: ...Mounting 5 4 Dismantling RN S SA 44 Operating Instructions 09 2016 A5E32605810A 03 ...
Страница 48: ...Technical data 7 2 Stainless steel guide elements RN S SA 48 Operating Instructions 09 2016 A5E32605810A 03 ...
Страница 56: ...Appendix A 1 Technical support RN S SA 56 Operating Instructions 09 2016 A5E32605810A 03 ...