![Siemens SIWAREX WL230 BB-S SA Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/siemens/siwarex-wl230-bb-s-sa/siwarex-wl230-bb-s-sa_operating-instructions-manual_374535056.webp)
Variable
Value
Rated measuring path h
n
For E
max
= 10 kg:
For E
max
= 20 kg:
For E
max
= 50 kg:
For E
max
= 100 kg:
For E
max
= 200 kg:
For E
max
= 300 kg:
For E
max
= 400 kg:
For E
max
= 500 kg:
≤ 0.03 mm
≤ 0.08 mm
≤ 0.15 mm
≤ 0.12 mm
≤ 0.15 mm
≤ 0.18 mm
≤ 0.17 mm
≤ 0.19 mm
Recommended supply voltage
5 to 12 V DC
Maximum supply voltage
18 V DC
Rated characteristic value C
Rated
2.0 ± 0.2 mV/V
Tolerance of zero signal D
o
< ± 2.0% C
n
Input resistance R
i
for E
max
10, 20, 50
380 ± 15 Ω
for E
max
100, 200, 300, 400, 500
350 ± 3.5 Ω
Insulation resistance R
is
≥ 5000 MΩ (at 50 V DC)
Rated temperature range B
tn
- 10 to + 40 °C
Operating temperature range B
tu
- 35 to + 65 °C
Storage temperature range B
ts
- 35 to + 65 °C
Sensor material
Stainless steel, mat. no. 1.4542
Degree of protection according to
EN 60 529
IP68, IP69K
Cable connection
Shielded PU cable,
3 m
Maximum tightening torque of the
fixing screws
for Emax = 10 to 50 kg
10 Nm
for Emax = 100 to 500 kg
20 Nm
1)
also available with E
max
/ 20000
9.1.8
SIWAREX WL250 ST-S SA
Table 9-8
Technical data SIWAREX WL250 ST-S SA
Variable
Value
Type series
WL250
Designation
ST-S SA
Construction type
S type load cell
Technical data
9.1 Functional data
SIWAREX WL200
56
Operating Instructions, 12/2021, A5E02199611B-13
Содержание SIWAREX WL230 BB-S SA
Страница 6: ...Table of contents SIWAREX WL200 6 Operating Instructions 12 2021 A5E02199611B 13 ...
Страница 10: ...Introduction 1 6 Notes on warranty SIWAREX WL200 10 Operating Instructions 12 2021 A5E02199611B 13 ...
Страница 24: ...Installing 4 3 Dismantling SIWAREX WL200 24 Operating Instructions 12 2021 A5E02199611B 13 ...