Commissioning
6.3 Adjustment and initial commissioning
SIWAREX WL200
Operating Instructions, 07/2016, A5E02199611B-03
33
6.3
Adjustment and initial commissioning
WARNING
Missing type of protection and loss of approval
If the load cell is not operated with an intrinsically safe power supply, the type of protection -
intrinsically safe is no longer guaranteed and the intrinsically safe approval may be
revoked.
Permanently erase, therefore, the irrelevant types of protection on the rating plate before
commissioning, so that erroneous deployment can be avoided.
6.3.1
Height compensation
6.3.1.1
When is height compensation necessary?
If you are using up to three load cells, all the load cells will always be under load. Height
compensation is not necessary in this case.
When an elastic base or elastic foundations are used, the height from the base or
foundations is compensated. Height compensation is not necessary in this case.
For more than three load cells or support points, the load bearing is statically indeterminate.
When the foundation and the base are rigid, the total weight can load two diagonally
mounted load cells and cause overloading of the load cells. Height compensation is
necessary in this case.
6.3.1.2
Procedure for height compensation
Determining the load on the load cells
1.
Bring the force transfer points to the same height.
The output signals for all load cells should be approximately identical when the load is
evenly distributed; and they will indicate the load distribution in the case of uneven
distribution.
2.
Measure the loading on the load cells as follows:
–
Disconnect the load cell cables SIG+ and SIG-.
–
Connect the supply voltage, e.g. 10.2 V, to the load cells.
–
Measure the output voltages between SIG+ and SIG- for the individual load cells.
3.
Determine which load cell has the lowest output voltage.
Содержание SIWAREX WL200 Series
Страница 6: ...Table of contents SIWAREX WL200 6 Operating Instructions 07 2016 A5E02199611B 03 ...
Страница 12: ...Safety instructions 2 4 Use in hazardous areas SIWAREX WL200 12 Operating Instructions 07 2016 A5E02199611B 03 ...
Страница 20: ...Installing 4 3 Dismantling SIWAREX WL200 20 Operating Instructions 07 2016 A5E02199611B 03 ...
Страница 90: ...Dimension drawings 10 16 SIWAREX WL290 DB S CA SIWAREX WL200 90 Operating Instructions 07 2016 A5E02199611B 03 ...
Страница 100: ...Appendix A 1 Technical support SIWAREX WL200 100 Operating Instructions 07 2016 A5E02199611B 03 ...
Страница 102: ...Index SIWAREX WL200 102 Operating Instructions 07 2016 A5E02199611B 03 W Wheatstone bridge 14 ...