Bit No.
Name
Range of Values / Meaning
Reference
23 Reserved
Reserved
24 Reserved
Reserved
25
Empty message
Scale in empty range
26
Calibration data protection
The switch for protecting the calibration data is switched on
27 Reserved
Reserved
28 Reserved
Reserved
29 Reserved
Reserved
30 Standalone
operation
activated
1, if standalone operation has been activated
31
Operating error
At least one operating error (fault) exists
Table 5-14
DR 30 - NAWI status bits
5.15.2 DR 30 - Conti-Status Flags
Bit No.
Name
Range of Values / Meaning
Reference
0
Belt control status
0: Belt control OFF
1: Belt control ON
1 Totalizing
status
1: Recording and totalizing of the dosing quantity is active
0: Dosing quantity will not be recorded
2
Min. belt loading exceeded
Belt loading min has been exceeded (is returned with a
delay in cases)
3
Belt loading max. exceeded
Belt max has been exceeded (is indicated with a delay in
cases)
4
Min. belt speed exceeded
Min. belt speed exceeded (returned with a delay in cases)
5
Max. belt speed exceeded
Max. belt speed exceeded (is indicated with a delay in
cases)
6
Min. pulse undercut
1 = Pulse encoder generates less than 2 pulses / second
0 = Pulse encoder generates a minimum of 2 pulses /
second
7
Min. belt load exceeded for
totalizing
1= Min. belt load exceeded for totalizing, the totalizing can
be performed
8
Scale in dynamic zero
setting range
=1, if the scale is in the dynamic zero setting range
9
Dynamic adjustment or zero
setting procedure is running
=1, if dynamic adjustment or zero setting procedure is
running
10
Dyn. zero setting aborted
1: If dynamic zero setting could not be completed or was
ended early because of leaving the zero setting range
11
Volumetric operation
Volumetric operation in automatic mode.
12
Filling Filling
activated.
13
> max. flow rate +/-
Change speed of flow rate too great
14
> min. flow rate
Minimum flow rate achieved
15
> max. flow rate
Maximum flow rate exceeded (in relation to the nominal
flow rate or setpoint)
16
Pulse 1 external
Pulses f. external summator 1
17
Pulse 2 external
Pulses f. External summator 2
18
Gravimetric operation
Gravimetric mode in automatic operation.
19
Emptying activated
The command for emptying was activated. Scale will not
refill, the container will empty until the limit value "Empty
range" from DR 4.
20
Max. control difference
Maximum control difference exists.
21
Reserved Reserved
22
Max. filling time
The maximum filling time has been achieved.
23
Max. time max. control
difference
The maximum control difference is at the max. defined
monitoring time.
24
Max. vol. time
The volumetric mode is active longer than the defined
max. monitoring time.
25 Reserved
Reserved
SIWAREX FTC