Commands
SIWAREX FTA
6-135
Code Command explanation
Executable
in following
operating
states
126
Display calibratable log values
Displays the calibratable log values Log ID, Gross or
Net, Tare, Total 1 and Setpoint in sequence at 4-
second intervals, then returns to the original value.
(Currently not operable via SIWATOOL)
127
Residual weighing without emptying
Emptying is stopped. The previously emptied
quantity is added to the current total 1. Cycle ends
without further emptying.
AWI totalizing
weighing cycle,
empty
Table 6-1
SIWAREX FTA command list
The commands in the table above can be activated over all interfaces.
More commands can be activated on the SIMATIC S7 interface of the FB SIWA_FTA.
Command
group
Description
1... 199
Commands are passed on to the module group without reading or writing from or to
data records (scale, weighing, logging commands). The meanings of these
commands correspond with the settings in table 6-1
Command list of
SIWAREX FTA
200 + X
Reading a data record. X is the data record number.
Example:
Reading data record 3 from FTA to CPU
200 + 3 = command code
203
400 + X
Writing a data record. X is the data record number.
Example:
Writing data record 3 from CPU to FTA
400 + 3 = command code 403
601... 699
601
602
610
649
Range for combined commands. The function block SIWA_FTA (FB41^) can
transfer several data records in sequence.
Read DR30 and DR31
Read DR34 and DR35
Read DR20 and DR22
Read all data records from the SIWAREX FTA (DR3, DR4, DR7, DR8, DR9, DR15,
DR18, DR20, DR21, DR22, DR23, DR26, DR30, DR31, DR32, DR34, DR35,DR39,
DR44, DR45, DR46, DR47, DR123)
Содержание SIWAREX FTA
Страница 1: ...SIWAREX FTA Device Manual Status 05 2017 ...