![Siemens SITRANS WW100 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/siemens/sitrans-ww100/sitrans-ww100_operating-instructions-manual_374523018.webp)
4. To change this value, press the key The display will begin to flash. Sequentially pressing
the key will increment
the display to the next higher digit.
5. Use or
arrows to set the RPM value (as calculated above).
6. Press
to accept the new value and exit edit mode (display will stop flashing).
Note
Although this value has been changed, it has only been saved in RAM memory. A RAM to
ROM must be performed in order to be maintained.
7. To save this new setting, press and hold
for 3 seconds. The display will begin to flash
indicating the RAM to ROM function is active. This will perform a RAM to ROM backup of all
parameters.
P1113 - Belt direction
P1113 – SetPoint Inversion Parameter. Drive 02 parameter
If the belt is travelling in reverse, change P1113 setting to alternate value.
The design of the WW100 weighfeeder is such that the servo Gear motor can be mounted on
either the left or right hand side of the weighfeeder. Given the versatility of the configuration, it
is necessary for the motor shaft output to be reversible. Therefore, parameter P1113 can be set
to accommodate a forward or reverse operation. However, one must note that the BOP display
for RPM may reflect a negative - 0.00 value. This is not a concern to the operator or
maintenance staff for regular operation of the drive.
If the weighfeeder is set up and you realize the belt is traveling in the reverse direction, proceed
as follows:
1. Set S120 display to drive number 02 (see Switching units (Page 16)).
2. Use or
arrows to navigate to P1113.
3. Press
so the current parameter value is displayed.
4. Press to activate edit mode (display will flash).
5. Use or
arrows to set the value to either 0 or 1 (whichever is the alternate).
6. Press
to accept the new value, and exit edit mode (display will stop flashing).
Note
Although this value has been changed, it has only been saved in RAM memory. A RAM to
ROM must be performed in order to be maintained.
7. To save this new setting, press and hold
for 3 seconds. The display will begin to flash
indicating the RAM to ROM function is active. This will perform a RAM to ROM backup of all
parameters.
Installing
4.2 Electrical installation for servo driven models
SITRANS WW100
18
Operating Instructions, 06/2018, A5E33560618-AC
Содержание SITRANS WW100
Страница 6: ...Introduction 1 1 The manual SITRANS WW100 6 Operating Instructions 06 2018 A5E33560618 AC ...
Страница 26: ...Connecting SITRANS WW100 26 Operating Instructions 06 2018 A5E33560618 AC ...
Страница 40: ...Troubleshooting 9 1 Mechanical troubleshooting SITRANS WW100 40 Operating Instructions 06 2018 A5E33560618 AC ...