![Siemens SITRANS WM300 MFA Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/siemens/sitrans-wm300-mfa/sitrans-wm300-mfa_operating-instructions-manual_374518042.webp)
Parameter assignment
6.5 Slow speed
SITRANS WM300 MFA
42
Operating Instructions, 08/2018, A5E45090709-AA
6.5.6
Process variable overview display
Note
Overview display alternates between input I3 and input I4 configured in programming and
cannot be changed to a display - only one channel.
Previous time period in seconds between the last pulse and the previous pulse. This can be
used as a guide to understand timing between pulses at any time in the process.
Current time is since the last pulse and will continue to increase until the next consecutive
pulse is observed on the input.
Probe Input I3 – Output Q1 & Q3
Q1
Alarm Off = maintained HI output.
Q1
Alarm On = maintained LO output
Q3
Alarm Off = maintained HI output.
Q3
Alarm On = maintained LO output.
Probe Input I4 – Output Q2 & Q4
Q2
Alarm Off = maintained HI output.
Q2
Alarm On = maintained LO output.
Q4
Alarm Off = maintained HI output.
Q4
Alarm On = maintained LO output.
Содержание SITRANS WM300 MFA
Страница 6: ...Table of contents SITRANS WM300 MFA 6 Operating Instructions 08 2018 A5E45090709 AA ...
Страница 10: ...SITRANS WM300 MFA Overview SITRANS WM300 MFA 10 Operating Instructions 08 2018 A5E45090709 AA ...
Страница 17: ...Installing mounting 3 5 Wiring SITRANS WM300 MFA Operating Instructions 08 2018 A5E45090709 AA 17 ...
Страница 25: ...Connecting 4 1 Interconnection SITRANS WM300 MFA Operating Instructions 08 2018 A5E45090709 AA 25 ...
Страница 28: ...Connecting 4 2 Connection to Power SITRANS WM300 MFA 28 Operating Instructions 08 2018 A5E45090709 AA ...
Страница 30: ...Service and maintenance 5 2 Maintenance SITRANS WM300 MFA 30 Operating Instructions 08 2018 A5E45090709 AA ...
Страница 31: ...SITRANS WM300 MFA Operating Instructions 08 2018 A5E45090709 AA 31 Parameter assignment 6 6 1 Menu structure ...
Страница 54: ...Troubleshooting 7 1 Troubleshooting SITRANS WM300 MFA 54 Operating Instructions 08 2018 A5E45090709 AA ...
Страница 58: ......
Страница 66: ......
Страница 78: ...Applications B 10 Non ferrous Window SITRANS WM300 MFA 78 Operating Instructions 08 2018 A5E45090709 AA ...
Страница 80: ...Support C 2 Certificates SITRANS WM300 MFA 80 Operating Instructions 08 2018 A5E45090709 AA ...