SITRANS WF100
Operating Instructions, 02/2012, 7ML19985NB01-01
37
Technical data
8
Accuracy
± 1 % of full scale, higher accuracy with linearizing function of integrator
Accuracy subject to: On factory approved installations the flowmeter system’s totalilzed weight will be
within the specified accuracy when compared to a known weighed material test sample. The test
rate must be within the specified range of the design capacity and held constant for the duration of
the test. The minimum material test sample must be equivalent to a sample obtained at the test
flow rate for at least ten minutes running time.
Load cell
construction
17-4 PH (1.4568) stainless steel construction with
304 (1.4301) stainless steel cover.
degree of protection
IP67 rated
excitation
10 V DC nominal, 15 V DC maximum
output
2 mV/V excitation at rated load cell capacity
non-linearity
0.02% of rated output
hysteresis
0.02% of rated output
non-repeatability
0.01% of rated output
capacity
2, 5, 10, 20 lb
overload
safe 150% of rated capacity
ultimate 300% of rated capacity
temperature
-40 to 75ºC (-40 to 167ºF) operating range
-18 to 65ºC (0 to 150ºF) compensated
Nominal sizes
100, 150, 200, 250 mm (4, 6, 8, 10")
Flow rate
3 to 200 t/h (4 to 220 STPH)
Содержание SITRANS WF100
Страница 1: ...SITRANS Solid Flowmeters SITRANS WF100 Operating Instructions 02 2012 ...
Страница 6: ...Table of contents SITRANS WF100 4 Operating Instructions 02 2012 7ML19985NB01 01 ...
Страница 8: ...Introduction SITRANS WF100 6 Operating Instructions 02 2012 7ML19985NB01 01 ...
Страница 22: ...Description 3 1 Material feed examples SITRANS WF100 20 Operating Instructions 02 2012 7ML19985NB01 01 ...
Страница 26: ...Installing Mounting SITRANS WF100 24 Operating Instructions 02 2012 7ML19985NB01 01 ...
Страница 28: ...Connecting SITRANS WF100 26 Operating Instructions 02 2012 7ML19985NB01 01 ...
Страница 32: ...Commissioning SITRANS WF100 30 Operating Instructions 02 2012 7ML19985NB01 01 ...
Страница 42: ...Technical data SITRANS WF100 40 Operating Instructions 02 2012 7ML19985NB01 01 ...
Страница 44: ...Dimension drawings SITRANS WF100 42 Operating Instructions 02 2012 7ML19985NB01 01 ...