Electrical data
Devices for general use
Measured current
I
Measuring
0,3 ... 1.0 mA
Devices in explosion-protected version
Equipment protection by means of intrinsic safety
For connecting to circuits with the following peak
values
U
i
≤ 30
V
I
i
≤ 100
mA
P
i
= P
o
(transmitter)
C
i
= 700 pF/m
L
i
= 15 µH/m
Equipment protection by means of non incendive
For connecting to circuits with the following peak
values
U
n
= 30 V
U
max
= 32 V
1)
1)
Maximum safety voltage
Equipment protection by means of Explosionproofed / Dust-Ignition proofed
For connecting to circuits with the following peak
values
U
max
= 45 V
P = 25/37/50/100 mW
8.4
Measuring tolerances for resistance thermometers
Tolerance classes
The tolerance classes of the resistance thermometers are defined as follows in accordance with IEC 60751:
Tolerance class
Precision
∆
t
Class B
Basic accuracy
±(0.30 °C +0.0050|t[°C]|)
±1.8x0.30 °F +0.0050x|t[°F]-32|
Class A
Increased accuracy
±(0.15 °C +0.0020|t[°C]|)
±1.8x0.15 °F +0.0020x|t[°F]-32|
Class AA (1/3 B)
High accuracy
±(0.10 °C +0.0017|t[°C]|)
±1.8x0.10 °F +0.0017x|t[°F]-32|
Tolerances
The following tables provide an overview of the validity ranges of these tolerances. When you use a thermometer above the
specified limits, the values of the next lower accuracy class apply.
Action
Tolerance
Precision
Range [°C (°F)]
Basic version
Class B
Basic accuracy
-50 ...400 (-58 ... +752)
Class A
Increased accuracy
-30°... 300 (-58 ... +572)
Class AA (1/3 B)
High accuracy
0°... 150 (32 ... 302)
With increased
vibration resistance
Class B
Basic accuracy
-50°... 400 (-58 ... +752)
Class A
Increased accuracy
-30°... 300 (-58 ... +662)
Class AA (1/3 B)
High accuracy
0°... 150 (32 ... 302)
With extended
measuring range
Class B
Basic accuracy
-196 ... 600 (392 ... 1112)
Class A
Increased accuracy