Rated conditions
Degree of protection (to EN 60529)
● IP65 with connector to EN 175301-803-A
● IP67 with M12 connector
● IP67 with cable
● IP67 with fast-fit cable gland
Electromagnetic compatibility
● To EN 61326-1
● To EN 61326-2-3
● To NAMUR NE21, only for ATEX devices and
with a max. measurement error of ≤ 1%
Construction
Weight
Approx. 0.090 kg (0.198 lb)
Process connections
Dimension drawings (Page 31)
Electrical connections
● Connector to EN 175301-803-A Form A with cable inlet M16x1.5
or ½-14NPT or Pg 11
● M12 connector
● 2 or 3-wire (0.5 mm
2
) cable (∅ ± 5.4 mm)
● Fast-fit cable gland
Material of the wetted parts
● Measuring cell
Stainless steel, Mat. No. 1.4016
● Process connection
Stainless steel, Mat. No. 1.4404 (SST 316 L)
Material of the non-wetted parts
● Enclosure
Stainless steel, Mat. No. 1.4404 (SST 316 L)
● Rack
● Plastic
● CuZn, nickel-plated (M12 connector)
● Cable
PVC spec.
Explosion protection 7MF1567-....1-....
Intrinsic safety "i" (only with current output)
●
II 1/2 G Ex ia IIC T4 Ga/Gb
●
II 1/2 D Ex ia IIIC T125 °C Da/Db
EC type-examination certificate
SEV 10 ATEX 0146
Connection to certified intrinsically-safe resistive
circuits with maximum values
U
i
≤ 30 VDC; I
i
≤ 100 mA; P
i
≤ 0.75 W
Effective internal inductance and capacitance for
versions with connections to EN 175301-803-A
and M12
L
i
= 0 nH; C
i
= 0 nF
Technical specifications
SITRANS P220
Compact Operating Instructions, 02/2019, A5E03304437-AB
29