![Siemens SITRANS LR200 7ML5422 Скачать руководство пользователя страница 114](http://html.mh-extra.com/html/siemens/sitrans-lr200-7ml5422/sitrans-lr200-7ml5422_operating-instructions-manual_384663114.webp)
SITRANS LR200 with mA/HART
114
Operating Instructions, 05/2019, A5E32337676-AE
Up sampling (2.8.5.2.)
Description
Specifies the number of consecutive echoes that must appear above the echo
currently selected, before the measurement is accepted as valid.
Values
Range: 1 to 50
Factory setting
5
Down sampling (2.8.5.3.)
Description
Specifies the number of consecutive echoes that must appear below the echo
currently selected, before the measurement is accepted as valid.
Values
Range: 1 to 50
Factory setting
2
7.2.7.6
Echo quality (2.8.6.)
Confidence (2.8.6.1.)
Description
Indicates echo reliability: higher values represent better echo quality. The display
shows the echo confidence of the last measurement. Echo threshold (2.8.4.3.)
(Page 112) defines the minimum criterion for echo confidence.
Values (view only) 0 to 99
Factory setting
---
shot not used
Related
parameters
Echo threshold (2.8.4.3.) (Page 112)
Echo strength (2.8.6.2.)
Description
Displays the absolute strength (in dB above 1
μ
V rms) of the echo selected as
the measurement echo.
Values (view only) –20 to 99
Noise average (2.8.6.3.)
Noise Average displays the average ambient noise (in dB above 1
μ
V rms) of a noise profile.
Noise level is a combination of transient noise and receiving circuitry. After a measurement,
the values from the previous noise shot will be displayed.
Содержание SITRANS LR200 7ML5422
Страница 185: ...SITRANS LR200 with mA HART Operating Instructions 05 2019 A5E32337676 AE 185 B 5 4 PFTE rod antenna threaded connection ...
Страница 193: ...SITRANS LR200 with mA HART Operating Instructions 05 2019 A5E32337676 AE 193 ...
Страница 194: ...SITRANS LR200 with mA HART 194 Operating Instructions 05 2019 A5E32337676 AE ...
Страница 212: ...Index SITRANS LR200 with mA HART 212 Operating Instructions 05 2019 A5E32337676 AE ...