![Siemens SITRANS FM MAG 8000 IIoT Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/siemens/sitrans-fm-mag-8000-iiot/sitrans-fm-mag-8000-iiot_operating-instructions-manual_1265487039.webp)
Parameter assignment
8
8.1
Parameter list
Parameter
Description
Default
value
Min. val‐
ue
Max. value
Log Verbosity Level
1)
Defines the information saved on the mi‐
croSD card.
• 0 : disabled
• 1 : error
• 2 : warnings
• 3 : error + wa info
Please be aware of higher battery con‐
sumption and microSD memory usage.
Siemens recommends keeping the default
value.
1
0
3
Firmware Version
Firmware Version of the IIoT Wireless Com‐
munication Module.
Read only
Network Signal Strength
Network Signal Strength from 0 (lowest)
to 5 (strongest).
Read only
Paging Interval
1)
Paging interval (in seconds) where the IIoT
Wireless Communication Module wakes
up and connects to the mobile network to
execute any read/write requests.
The lower the value, the higher the bat‐
tery consumption.
Recommendation: Configure this parame‐
ter to less than one hour only for startup
and then set it back to greater than one
hour for regular operation.
3600
300
2678400
Timestamp
UTC Unix time → always GMT in seconds
from 1970
Read only
Paging Control
Enable paging interval (if disabled, the
read/write requests will be executed dur‐
ing transmission intervals).
true
false
true
Auto Adaptive Control
Sets up the transmission interval to 30 min
in case the MAG 8000 is in mains powered
operation.
false
false
true
Last Interval Modification Time
Not active in current release.
Read only
Analog Value 1
Value in millivolts [0 - 5000]. Returns 0 if
“Analog Inputs Acquisition Control" is dis‐
abled.
Read only
Analog Value 2
Read only
Battery Remaining
Capacity of the MAG 8000 main battery in
%
Read only
SITRANS FM MAG 8000 IIoT Wireless Communication Module
Operating Instructions, 07/2022, A5E52070595A-AA
39