7.1.7
Diagnostic views
Six Diagnostic Values
4
3
5
1
6
2
①
First process/diagnostic
value
The user-defined process value to be displayed is configured in
menu "View" (1-6) located at "Setup" → "Local display" (menu item
2.8).
②
Second process/diag‐
nostic value
The user-defined process value to be displayed is configured in
menu "View" (1-6) located at "Setup" → "Local display" (menu item
2.8).
③
Third process/diagnostic
value
The user-defined process value to be displayed is configured in
menu "View" (1-6) located at "Setup" → "Local display" (menu item
2.8).
④
Fourth process/diagnos‐
tic value
The user-defined process value to be displayed is configured in
menu "View" (1-6) located at "Setup" → "Local display" (menu item
2.8).
⑤
Fifth process/diagnostic
value
The user-defined process value to be displayed is configured in
menu "View" (1-6) located at "Setup" → "Local display" (menu item
2.8).
⑥
Sixth process/diagnostic
value
The user-defined process value to be displayed is configured in
menu "View" (1-6) located at "Setup" → "Local display" (menu item
2.8).
7.1.8
Navigation view
The navigation views present the menu structure of the device. All menu items are uniquely
identified with menu item number.
Level 1 of the navigation view (entered from the operation view) is standardized for all Siemens
Process Instrumentation devices and covers the following groups:
1. Quick Start (menu): Lists the most important parameters for quick configuration of the
device. All parameters in this view can be found elsewhere in the menu.
2. Setup (menu): Contains all parameters which are needed to configure the device.
3. Maintenance & Diagnostics (menu): Contains parameters which affect the product behavior
regarding maintenance, diagnostics and service.
Examples: Verification, failure prediction, device health, data logging, alarm logging, report,
condition, monitoring, tests, etc.
4. Communication (menu): Contains parameters which describe the Profibus, Profinet, HART,
Modbus, X-bus communication settings of the device.
Operating
7.1 Local operation (HMI)
SITRANS FC330
Operating Instructions, 01/2019, A5E44030648-AB
117
Содержание SITRANS FC330
Страница 14: ...Introduction 1 8 Notes on warranty SITRANS FC330 14 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 56: ...Installing mounting 4 3 Disassembly SITRANS FC330 56 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 126: ...Operating 7 2 Remote operation SITRANS FC330 126 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 158: ...Parameter assignment 8 2 Functions SITRANS FC330 158 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 216: ...Technical data 11 13 Pressure temperature ratings SITRANS FC330 216 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 224: ...Dimension drawings 12 7 Mounting bracket dimensions SITRANS FC330 224 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 236: ...HART communication B 1 Mode of operation HART function SITRANS FC330 236 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 274: ...Zero point adjustment SITRANS FC330 274 Operating Instructions 01 2019 A5E44030648 AB ...
Страница 280: ...Index SITRANS FC330 280 Operating Instructions 01 2019 A5E44030648 AB ...