
Operating
7.2 Operating the FST030
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
74
Operating Instructions, 08/2017, A5E37367739-AC
Fixed display text
Diagnostic value name
P1.ACC.BURST
Path 1 percentage of bursts accepted
P1.PEAK AMP.DN
Peak amplitude down path 1
P1.PEAK AMP.UP
Peak amplitude up path 1
P2.SNR UP
SNR up path 2
P2.SNR DOWN
SNR down path 2
P2.SOUND VEL
Sound velocity path 2
P2.DELTA TIME
Delta time path 2
P2.ACC.BURST
Path 2 percentage of bursts accepted
P2.PEAK AMP.DN
Peak amplitude down path 2
P2.PEAK AMP.UP
Peak amplitude up path 2
Table 7- 3
Compensation values
Fixed display text
Diagnostic value name
MEDIUM TEMP.
Temperature
PRESSURE *
Pressure
KIN.VISCOSITY *
Kinematic viscosity
DENSITY *
Density
7.2.2
Reading the process values
The current value of the process values can be displayed either as one or more numeric
values or as numeric value(s) in combination with a graph/bargraph. The following view
types are available:
●
Single value
●
Three values
●
Totalizer
●
1 value and graph
●
1 value and bargraph
●
Six values
Table 7- 4
Key functions - operator view
Key
Function
No functionality
Go to the previous operator view
Go to the next operator view
Enter the menu structure access point
Содержание SITRANS F Series
Страница 2: ......
Страница 360: ...Index SITRANS F Ultrasonic flowmeters FST030 Modbus 358 Operating Instructions 08 2017 A5E37367739 AC ...
Страница 361: ......