Modbus communication
A.9 Modbus holding registers tables
SITRANS F Ultrasonic flowmeters FST030 (Modbus)
158
Operating Instructions, 08/2017, A5E37367739-AC
Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[units]
(units regis-
ter)
Value range /
Setting options
Access
level
1719
Float / 4
Calibration
reference pres-
sure
Setup parameter for
specifying the process
pressure at which the
flow calibration of the
meter is performed.
The value is used for
compensation of pipe
expansion due to pres-
sure.
700000.0
[Pa]
(8015)
0.0 - 100000000.0
Read /
write
1721
Float / 4
Pipe modulus
elasticity
Setup parameter for
specifying the pipe
material modulus of
expansion. The value
is used for compensa-
tion of pipe expansion
due to pressure.
200.0E+9
[Pa]
(8015)
1.0E+6 - 1.0E+12
Read /
write
Upstream and downstream conditions
Table A- 16 Upstream and downstream conditions
Modbus
register
Data type /
Size in bytes
Parameter
Description
Default value
[units]
(units regis-
ter)
Value range /
Setting options
Access
level
1220
Unsigned / 2 Upstream pipe
geometry
Compensation for
upstream pipe geome-
try.
0
•
0: Straight run
•
1: Single elbow
•
2: Double elbow (in-
plane)
•
3: Double elbow (out-
of-plane)
•
4: Reducer
•
5: Expansion
Read /
write
1221
Unsigned / 2 Upstream dis-
tance
The distance to the
upstream flow disturb-
ance in multiples of
inner pipe diameter.
0
0 - 40
Read /
write