![Siemens SITRANS F M Verificator Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/siemens/sitrans-f-m-verificator/sitrans-f-m-verificator_operating-instructions-manual_1266075012.webp)
Sensor:
No SENSORPROM
Press GO to continue
3.3
Verificator software - sensor - Insulation
If a SENSORPROM
®
unit is install, then the verification test will continue with the insulation test.
The bar indicates how the test is progressing.
Press ESC to cancel the test.
T2:3 Insulation test
0%- ##
-100%
Press ESC to cancel
Insulation test finished
Press ESC to cancel further tests.
T2:3 Insulation test
0% -###############
-100%
Press ESC to cancel
Is only displayed if the insulation resistance of the sensor/system is insufficient. See "On site
trouble shooting".
Value shows the measured value in nV.
Press ESC to quit.
E2: Sensor failed
Insulation fault
Value xxxxxx xxx
Press ESC to quit
Sensor/system passed the insulation test
Verification continues automatically.
I2: Sensor Passed
Insulation OK
Please wait ....
Operating (hardware)
3.3 Verificator software - sensor - Insulation
SITRANS F M Verificator
12
Operating Instructions, 07/2019, A5E45134218-AB
Содержание SITRANS F M Verificator
Страница 4: ...Table of contents SITRANS F M Verificator 4 Operating Instructions 07 2019 A5E45134218 AB ...
Страница 6: ...Introduction SITRANS F M Verificator 6 Operating Instructions 07 2019 A5E45134218 AB ...
Страница 38: ...Technical Data SITRANS F M Verificator 38 Operating Instructions 07 2019 A5E45134218 AB ...