Connecting
5
This chapter consists of general safety requirements as well as a description of how to connect
the device.
The connection of the device is done in four steps.
1. Wiring sensor and transmitter (remote version only).
2. Connecting power supply.
3. Connecting outputs.
4. Connecting add-on module.
Connection diagram
①
Module Interface (Option)
②
Output A
③
Output B
The 3.6 V DC battery connector - male and pulse connection terminals are placed in the right
side of the PCB board - see figure.
Connection for add-on interface modules is placed on the left side.
HL = Hardware lock key connection
V = Verification button (enables verification mode for 4 hours)
To configure the outputs via PDM, see "Output configuration" (Page 53).
To configure the outputs via Flow Tool, see "Output configuration" (Page 125) in the Flow Tool
appendix.
SITRANS MAG 8000
Operating Instructions, 11/2018, A5E03071515-AE
31