Technical data
6
Note
Technical data is applicable for a rated input voltage of 230 VAC, rated load and +25° C
ambient temperature (if nothing else is specified).
6.1
Input
6EP1333-3BA10
(24 V/5 A)
6EP1334-3BA10
(24 V/10 A)
6EP1336-3BA00
(24 V/20 A)
6EP1337-3BA00
(24 V/40 A)
Input
1-phase and 2-phase AC
Rated voltage value
Ue rated
120...230 / 230...500 V 120...230 / 230...500 V 120/230 V
120/230 V
Voltage range
•
Remark
85...264 / 176...550 V
Setting via selector
switch on the device;
starting from Ue >
90/180 V
Derating for -25 to
0 °C:
Starting with max.
500 V
85...264 / 176...550 V
Setting via selector
switch on the device;
starting from Ue >
90/180 V
Derating for -25 to
0 °C:
Starting with max.
500 V
85...132 / 176...264 V
Setting via wire jumper
on the device;
start-up as of Ue >
93/183 V
85...132 / 176...264 V
Setting via wire jumper
on the device;
start-up as of Ue >
95/190 V
Wide-range input
Yes
No
Overvoltage strength
2.3 × Ue rated, 1.3 ms
Power failure buffering
at Ia rated, min
25 ms
25 ms
20 ms
20 ms
Power-failure buffering For Ue = 120/230 V,
typ. 150 ms for Ue =
500 V
For Ue = 120/230 V,
typ. 150 ms for Ue =
500 V
at Ue = 230 V
at Ue = 230 V
Rated line frequency
50/60 Hz
Line frequency range
47...63 Hz
Input current / at rated
value of input voltage
120 V
2.2 A
4.4 A
7.7 A
15 A
Input current / at rated
value of input voltage
230 V
1.2 A
2.4 A
3.5 A
8 A
Input current / at rated
value of input voltage
500 V
0.61 A
1.1 A
-
-