3SU14 modules
8.1 Overview
SIRIUS ACT 3SU1 pushbuttons and signaling devices
System Manual, 08/2018, A5E03457306020A/RS-AK/010
171
8.1.3
Contact modules for front plate mounting
Contact modules for front plate mounting are installed on the rear face of a holder.
Contact modules with gold contacts have better protection against corrosion (e.g. in
sulfurous environments) and therefore a high contact reliability at low currents and low
operating frequencies.
For further information refer to Chapters "Holders (Page 213)" and "Mounting (Page 199)".
Number of NO
contacts
Number of NC
contacts
Product function
positive opening
Suitable for enclosure
mounting
Article number
Contact modules with silver contacts
Siemens Industry Mall (
http://mall.industry.siemens.com/mall/en/WW/Catalog/Products/10221526
1
0
No
Yes
3SU1400-1AA10-xBA0
0
1
Yes
Yes
3SU1400-1AA10-xCA0
2
0
No
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xDA0
0
2
Yes
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xEA0
1
1
Yes
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xFA0
1 leading
1 lagging
No
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xGA0
0
2 (1 contact for
installation
monitoring)
Yes
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xHA0
1)
Contact modules with gold contacts
1
0
No
Yes
3SU1400-1AA10-xLA0
0
1
Yes
Yes
3SU1400-1AA10-xMA0
2
0
No
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xNA0
0
2
Yes
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xPA0
1
1
Yes
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xQA0
1 leading
1 lagging
No
Yes, with accessory
3SU1900-0JF10-0AA0
3SU1400-1AA10-xRA0
x: 1 = screw terminals; 3 = spring-loaded terminals
1)
The 3SU1400-1AA10-.HA0 contact modules with installation monitoring can only be mounted at positions 1 and 2 on
the holder when combined with 3SU1 actuating and signaling elements.
Exception: They can be mounted at all 3 holder positions when they are combined with a non-illuminated EMERGENCY
STOP.