Note
A secure password is only valid for a single user account, is more than 8 characters long, and
contains uppercase and lowercase letters, special characters and numerals. Do not use any
common numeric sequences from the computer keyboard or words from the dictionary. Change
your password at regular intervals.
HMI User PIN
• 4-digit HMI User PIN
• Digits 0 ... 9
• A login with PIN is only possible via the 3RW5 HMI High Feature
Auto log off time
You will be automatically logged off on expiry of the programmable auto log off time (Page 237).
8.23.4
User login and logout
Operating principle
You can protect the 3RW55 and 3RW55 Failsafe soft starters against unauthorized access by
issuing PIN-protected user accounts.
You will find more information in chapter Setting up user account management (Page 240).
Requirements
• User account has been set up in SIRIUS Soft Starter ES (TIA Portal).
• User account has been transferred with SIRIUS Soft Starter ES (TIA Portal) via one of the
following paths to the 3RW55 or 3RW55 Failsafe soft starter:
– Local interface
– Fieldbus via a 3RW5 PROFINET or PROFIBUS communication module
– Micro SD card (only with the function "Device change" (Page 281))
• 3RW5 HMI High Feature
Menu: "Security"
Procedure for User login
1. Select the "User login" menu in order to log in with your user account.
2. Enter the 4-digit HMI User PIN.
After correctly entering the HMI User PIN you are logged in with your user account.
Functions
8.23 Local access protection and user account administration
SIRIUS 3RW55 and 3RW55 Failsafe Soft Starters
242
Equipment Manual, 02/2022, A5E35630887002A/RS-AF/006