Device functions
7.2 Startup modes
3RW44 soft starters
124
Manual, 03/2017, NEB535219502000/RS-AB/008
7.2.3
Breakaway pulse in combination with the voltage ramp or torque control startup
mode
This function is required for load machines with inverse torque behavior. Typical applications
are mills, crushers or drives with plain bearings. In such cases, it may be necessary to create
a breakaway pulse at the beginning of the machine's start process. The breakaway pulse is
set via the breakaway voltage and the breakaway time. Using the breakaway pulse, the high
limiting friction of the load can be overcome and the machine can be set into motion.
The breakaway pulse is used in conjunction with the start type of the voltage ramp, the
torque control, or the current limitation and overlays this during the set breakaway time.
Breakaway voltage
The breakaway voltage is used to set the breakaway torque to be generated. The breakaway
torque can be up to 100% of the locked-rotor torque generated during direct-on-line starting.
The pulse must be high enough to ensure that the motor starts rotating as soon as the start
command is issued to the soft starter.
Breakaway time
The breakaway time determines the period during which the breakaway voltage is to be
present. Once the breakaway time has expired, the soft starter ends its run-up procedure
with the selected startup mode, e.g. the voltage ramp or torque control. The selected
breakaway time should be at least long enough so that, after the set time has elapsed, the
motor does not remain stationary again but rather directly continues to accelerate in the
selected startup mode
If 0 ms is set as the breakaway time (default), the breakaway pulse function is deactivated.
Figure 7-4
Function principle of torque control breakaway pulse
Содержание SIRIUS 3RW44
Страница 1: ...Manual 3RW44 Soft Starters Edition Industrial Controls siemens com industrial controls 03 2017 ...
Страница 260: ...General technical data 11 3 Technical data 3RW44 soft starters 260 Manual 03 2017 NEB535219502000 RS AB 008 ...
Страница 261: ...General technical data 11 3 Technical data 3RW44 soft starters Manual 03 2017 NEB535219502000 RS AB 008 261 ...
Страница 262: ...General technical data 11 3 Technical data 3RW44 soft starters 262 Manual 03 2017 NEB535219502000 RS AB 008 ...
Страница 263: ...General technical data 11 3 Technical data 3RW44 soft starters Manual 03 2017 NEB535219502000 RS AB 008 263 ...
Страница 265: ...General technical data 11 3 Technical data 3RW44 soft starters Manual 03 2017 NEB535219502000 RS AB 008 265 ...
Страница 266: ...General technical data 11 3 Technical data 3RW44 soft starters 266 Manual 03 2017 NEB535219502000 RS AB 008 ...
Страница 271: ...General technical data 11 3 Technical data 3RW44 soft starters Manual 03 2017 NEB535219502000 RS AB 008 271 ...
Страница 272: ...General technical data 11 3 Technical data 3RW44 soft starters 272 Manual 03 2017 NEB535219502000 RS AB 008 ...
Страница 273: ...General technical data 11 3 Technical data 3RW44 soft starters Manual 03 2017 NEB535219502000 RS AB 008 273 ...
Страница 274: ...General technical data 11 3 Technical data 3RW44 soft starters 274 Manual 03 2017 NEB535219502000 RS AB 008 ...
Страница 276: ...General technical data 11 3 Technical data 3RW44 soft starters 276 Manual 03 2017 NEB535219502000 RS AB 008 ...