Appendix
A.11 Measured Values
SIPROTEC, 7SJ61, Manual
C53000-G1140-C210-1, Release date 02.2008
434
A.11
Measured Values
No.
Description
Function
IEC 60870-5-103
Configurable in Matrix
Ty
p
e
Inf
o
rm
a
tion
Num
b
e
r
Com
p
a
ti
b
il
it
y
Da
ta
U
n
it
Po
si
ti
on
CFC
Cont
ro
l D
is
p
la
y
D
e
fa
u
lt D
is
p
la
y
-
I A dmd> (I Admd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
I B dmd> (I Bdmd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
I C dmd> (I Cdmd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
I1dmd> (I1dmd>)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
37-1 under current (37-1)
Set Points(MV)
-
-
-
-
-
CFC
CD
DD
-
Number of TRIPs= (#of TRIPs=)
Statistics
-
-
-
-
-
CFC
CD
DD
-
Operating hours greater than (OpHour>)
SetPoint(Stat)
-
-
-
-
-
CFC
CD
DD
601
Ia (Ia =)
Measurement
134
137
No
9
1
CFC
CD
DD
602
Ib (Ib =)
Measurement
160
144
Yes
3
1
CFC
CD
DD
134
137
No
9
2
603
Ic (Ic =)
Measurement
134
137
No
9
3
CFC
CD
DD
604
In (In =)
Measurement
134
137
No
9
4
CFC
CD
DD
605
I1 (positive sequence) (I1 =)
Measurement
-
-
-
-
-
CFC
CD
DD
606
I2 (negative sequence) (I2 =)
Measurement
-
-
-
-
-
CFC
CD
DD
661
Threshold of Restart Inhibit (
Θ
REST. =)
Measurement
-
-
-
-
-
CFC
CD
DD
805
Temperature of Rotor (
Θ
Rotor)
Measurement
-
-
-
-
-
CFC
CD
DD
807
Thermal Overload (
Θ
/
Θ
trip)
Measurement
-
-
-
-
-
CFC
CD
DD
809
Time untill release of reclose-blocking (T re-
close=)
Measurement
-
-
-
-
-
CFC
CD
DD
830
INs Senstive Ground Fault Current (INs =)
Measurement
-
-
-
-
-
CFC
CD
DD
831
3Io (zero sequence) (3Io =)
Measurement
-
-
-
-
-
CFC
CD
DD
833
I1 (positive sequence) Demand (I1 dmd=)
Demand meter
-
-
-
-
-
CFC
CD
DD
837
I A Demand Minimum (IAdmdMin)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
838
I A Demand Maximum (IAdmdMax)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
839
I B Demand Minimum (IBdmdMin)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
840
I B Demand Maximum (IBdmdMax)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
841
I C Demand Minimum (ICdmdMin)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
842
I C Demand Maximum (ICdmdMax)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
843
I1 (positive sequence) Demand Minimum
(I1dmdMin)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
844
I1 (positive sequence) Demand Maximum
(I1dmdMax)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
851
Ia Min (Ia Min=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
852
Ia Max (Ia Max=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
853
Ib Min (Ib Min=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
854
Ib Max (Ib Max=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
855
Ic Min (Ic Min=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
856
Ic Max (Ic Max=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
857
I1 (positive sequence) Minimum (I1 Min=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
858
I1 (positive sequence) Maximum (I1 Max=)
Min/Max meter
-
-
-
-
-
CFC
CD
DD
888
Pulsed Energy Wp (active) (Wp(puls))
Energy
133
55
No
205
-
CFC
CD
DD
889
Pulsed Energy Wq (reactive) (Wq(puls))
Energy
133
56
No
205
-
CFC
CD
DD
963
I A demand (Ia dmd=)
Demand meter
-
-
-
-
-
CFC
CD
DD
964
I B demand (Ib dmd=)
Demand meter
-
-
-
-
-
CFC
CD
DD
965
I C demand (Ic dmd=)
Demand meter
-
-
-
-
-
CFC
CD
DD
Содержание SIPROTEC 7SJ61
Страница 368: ...Technical Data 4 22 Dimensions SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 368 ...
Страница 436: ...Appendix A 11 Measured Values SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 436 ...
Страница 438: ...Literature SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 438 ...
Страница 450: ...Glossary SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 450 ...
Страница 454: ...Index SIPROTEC 7SJ61 Manual C53000 G1140 C210 1 Release date 02 2008 454 ...