ASP Effect States
10
62 | 66
A6V11144326
10
ASP Effect States
The following table lists the Point Types and Properties that can be selected for
ASP Effect State.
Category Effect Type
Property
Property Values
Description
Input
Point
Regular
Effect
Input Enabled False
True
Enabled state of all the
input types except SPC.
Return to Time
Schedule
Control
True
Pulse command to
return to Time Control
Period.
Set Input
True
Command to set
Sintony input.
Clear Input
True
Command to clear
Sintony input.
Clear Isolate
Input
True
Command to clear
isolation of SPC Input.
Isolate Input
True
Command to isolate
Sintony/SPC input.
Stateless
Effect
Pulse Input
TrueTrue
Command to pulse
Sintony input.
Output
Point
Stateless
Effect
Toggle Output True
Toggles the door latch,
local, elevator state of
the output
Alternative
Effect
Dual State
Open
Closed
Output State of Door
Latch, Local, Elevator -
Open and Closed only
Regular
Effect
Unlock
Override
Interlock
True
Overrides the door
interlock state, setting
the state of the Latch
output to Unlock.
Stateless
Effect
Door Latch
Allow Access
Override Interlock
Overrides the door
interlock state setting
the state of the Latch
output to Allow Access
Single Pulse
Output
True
Unlock the output for a
single, short pulse
period for Door Latch
and Auxiliary.
Regular
Effect
Output Cancel
Perm
True
Cancel Permanent
Override Command.
Return to time
schedule
True
Return to Time Period
Control.
Stateless
Effect
Toggle
Auxiliary
True
Toggles the state of the
Auxiliary output.
Alternative
Effect
Aux Output
State
Open
Closed Pulse
Fast Pulse
Auxiliary Output state.