Controller Event Tasks
Sources
8
A6V11144326
41 | 66
8
Controller Event Tasks
SiPass
integrated
allows you to define a controller event task that performs a
certain task (command) when a specific set of circumstances have been met
(trigger).
Because controller event tasks are triggered by hardware events, you must select
what type of component triggers or responds to the event.
The following table lists the Types and States that can be selected when defining a
Trigger for a Controller Event Task.
8.1
Sources
Type
State (trigger)
Description
ACC Event Task
Cleared
Allows the operator to trigger a Controller
Event Task as a result of another Controller
Event Task.
The ACC controller event task selected in the
Source field has not been triggered or has
been reset.
Set
The ACC controller event task selected in the
Source field has been triggered.
Access Point
(logical)
“Daily Code” mode
set
Access Point mode set to Daily Code.
“No Additional
Access” mode set
Access Point mode set to No Additional
Access.
“No Dual Custody”
mode set
Access Point mode set to No Dual Custody
mode.
“PIN as Card” mode
set
Access Point mode set to Daily Code.
“Standard Dual
Custody” mode set
Access Point mode set to Daily Code.
“Supervisory Dual
Custody” mode set
Access Point mode set to Daily Code.
Disable Intrusion
Control
Intrusion Control is disabled on the access
point.
Dual Custody
Verification
Complete
Dual Custody verification has been completed
at the access point.
Enable Intrusion
Control
Intrusion Control has been enabled at the
access point.
Invalid Daily Code
An event task is triggered when an invalid daily
code has been entered at an access point.
Reader Online
An event task is triggered when a reader
enters the offline state. Only valid for the
Siemens reader range.
Reader Offline
An event task is triggered when a reader
enters the online state. Only valid for the
Siemens reader range.
Reader Tamper
An event task is triggered when a reader
enters the tamper state (tamper input
activated). Only valid for the Siemens reader
range.