Parameterizing machine data
3.2 Parameterizing the control using machine data
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
105
20098
DISPLAY_AXIS
Bits 16 to 31: MCS
Bit 16
= 1
= 0
Display machine axis in actual-value windows
Hide the machine axis in the actual-value windows.
Bit 17
Not assigned
Bit 18
= 1
= 0
Display machine axis in the base offset window
Hide machine axis in base offset window
Bit 19
= 1
= 0
Display machine axis in the handwheel selection window
Hide machine axis in the handwheel selection window
3.2.8
Memory for cycles in the DRAM
Overview
Cycles can be stored in the DRAM of the NCU. This makes more SRAM memory available
to the user for parts programs and workpieces.
Function
Under "Start-up" → "NC" → "NC Memory", the user interface for HMI-Advanced offers users
with corresponding access authorizations the possibility of determining the utilization of
DRAM and to adjust its size via MD 18351: MM_DRAM_FILE_MEM_SIZE. A change to the
DRAM memory causes a complete reorganization of the NCK memory.
NOTICE
You must save all relevant data before changing the memory sizes. If machine data is
changed then this results in a re-organization of the NCK memory.
Cycles saved in the DRAM
Via MD 11290: DRAM_FILESYSTEM_MASK can be used to set which objects should be
loaded in the DRAM:
Bit 0-n
= 0:
The data for the specified directory is to be stored in the SRAM.
= 1:
The data for the specified directory is to be stored in the DRAM.
Depending on MD 11291: DRAM_FILESYST_SAVE_MASK a copy is
kept in the FFS on the NC card.
Bit 0
CST directory (Siemens cycles)
Bit 1
CMA directory (machine manufacturer cycles)
Bit 2
CUS directory (user cycles)
Содержание SINUMERIK
Страница 6: ...Preface Base software and HMI Advanced 6 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 24: ...Introduction 1 5 Limits of data management HMI Advanced IM4 18 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 96: ......
Страница 338: ...List of Abbreviations B 1 Abbreviations HMI Advanced IM4 332 Commissioning Manual 03 2009 6FC5397 0DP10 3BA0 ...
Страница 464: ...Programming 2 8 Operators Expanding the user interface 2 114 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 562: ...Index Expanding the user interface Index 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 566: ...Table of contents Online Help HE1 4 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 598: ...Online Help HE1 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 36 ...
Страница 638: ...References for text generation Generating target language texts TX2 40 Commissioning Manual 11 2006 6FC5397 0DP10 0BA0 ...
Страница 672: ...Commissioning a system 1 4 BIOS settings PCU Basesoftware IM8 32 Commissioning Manual 03 2009 6FC5397 1DP10 4BA0 ...