6.3
Fix the NCU using spacers
Introduction
Spacers can be used to mount the NCU on a bare-metal highly-conductive rear panel of a
control cabinet.
Note
The mechanical stability for horizontal mounting is only guaranteed with the help of supports or
similar. These must be clarified depending on the specific application and are not part of this
documentation.
Procedure
Mount the NCU using two M6 screws (6 Nm tightening torque) on the spacers on the rear of the
control cabinet.
6.4
Mounting the NCU without spacers
Procedure
The NCU has spacers on the upper and lower rear side, each fixed with three Torx M3 screws
as delivered.
1. Remove the spacers with a T10 screwdriver.
2. At the top and bottom, fasten the metal lugs of the NCU directly to the rear panel of the
control cabinet using two M6 screws (6 Nm).
Installation
6.4 Mounting the NCU without spacers
NCU 1760
Equipment Manual, 02/2020, A5E45627861B AB
47
Содержание SINUMERIK ONE NCU 1760
Страница 8: ...Table of contents NCU 1760 8 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 36: ...Description 3 5 Dual fan module NCU 1760 36 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 44: ...Dimension drawings 5 1 NCU 1760 dimension drawing NCU 1760 44 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 48: ...Installation 6 4 Mounting the NCU without spacers NCU 1760 48 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 150: ...Connectable components 11 3 PP 72 48D PN 2 2A PN NCU 1760 150 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 154: ...Spare parts accessories 12 2 SD card NCU 1760 154 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 156: ...Safety symbols NCU 1760 156 Equipment Manual 02 2020 A5E45627861B AB ...
Страница 160: ...Appendix A 2 Documentation overview SINUMERIK ONE NCU 1760 160 Equipment Manual 02 2020 A5E45627861B AB ...