Supplementary conditions
During laying of the indoor bus cable, you must also consider the following supplementary
conditions (d
O
= outer diameter of the cable):
Table 8-17
Supplementary conditions for the laying of PROFIBUS cables
Characteristics
Supplementary conditions
Bending radius for a single bend
80 mm (10xd
O
)
Bending radius (multiple times)
160 mm (20xd
O
)
Permissible temperature range for cable routing
-5° C to +50° C
Temperature range for storage and stationary operation
-30° C to +65° C
8.9.5
Connecting PROFIBUS DP
Introduction
PROFIBUS cables are connected to the X126 interface via a bus connector.
Wiring the bus connector
1. Proceed as follows to connect the bus connector:
2. Plug the bus connector into the corresponding interface on the NCU.
3. Screw the bus connector into place.
As the NCU is located at the start or end of a segment, you must switch on the terminating
resistor ("ON" switch setting).
7HUPLQDWLQJUHVLVWRU
VZLWFKHGRQ
7HUPLQDWLQJUHVLVWRU
VZLWFKHGRII
RQ
RII
RQ
RII
Figure 8-7
Terminating resistor switched on and off
Note
Make sure that the stations on which the terminating resistor is located are always supplied
with voltage during ramp-up and operation.
Connecting
8.9 PROFIBUS DP
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA
77
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...