More information
More information on how to commission an NX component is provided in:
• Commissioning Manual IBN CNC: NCK, PLC, Drive
12.1.5
Technical Data
Table 12-9
Safety-related data
Protection class
III
Degree of protection to EN 60529
IPXXB
Approvals
CE, cULus
Pollution degree
2
Cooling
Open-circuit ventilation
Mounting position
Vertical
PE/ground connection
at the housing with M5 screw Torx / 3 Nm
Table 12-10 Electrical and mechanical data
Input voltage
24 V DC (20.4 – 28.8)
Current drain (without DRIVE-CLiQ and digital outputs) 0.3 A
Max. permitted output current
3.35 A
Power loss
15 W
Dimensions WxHxD (with spacers)
25 x 414 x 272 mm
Weight
2.58 kg
12.2
PP 72/48D PN
12.2.1
Description
Characteristics
I/O module PP 72/48D PN is a simple module (without a separate housing) for connecting digital
input/outputs as part of an automation system based on PROFINET IO.
The module has the following important characteristics:
• PROFINET IO connection (max. 100 Mbits/s)
• 72 digital inputs and 48 digital outputs
• On-board status display via 2 diagnostic LEDs
Connectable components
12.2 PP 72/48D PN
NCU 1740
Equipment Manual, 10/2021, A5E51087503B AA
109
Содержание SINUMERIK ONE NCU 1740
Страница 48: ...Dimension drawings 6 1 NCU 1740 dimension drawing NCU 1740 48 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 52: ...Installation 7 4 Mounting the NCU without spacers NCU 1740 52 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 96: ...Technical data 11 3 Recycling and disposal NCU 1740 96 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 156: ...Connectable components 12 3 PP 72 48D PN 2 2A PN NCU 1740 156 Equipment Manual 10 2021 A5E51087503B AA ...
Страница 160: ...Safety symbols NCU 1740 160 Equipment Manual 10 2021 A5E51087503B AA ...