06.03
15.3 Data backup
15-495
Siemens AG, 2003. All rights reserved
SINUMERIK 840Di Manual (HBI) – 06.03 Edition
When saving a partition C:, E: and F: an independent image file with the name
of the partition backup in front of it is created under D:\IMAGES for each of the 3
saved partitions, e.g.:
–
for partition C: IBNZWST.GH1
–
for partition E: IBNZWST.GH3
–
for partition F: IBNZWST.GH4
When restoring the partition backup, however, the 3 individual files will be ad-
dressed as one partition backup with the description entered under Point 6.
15.3.8
Changing the number of partition backups
From the menu displayed in the Subsection 15.3.7 under Point 4. (page
15-493), select
PLEASE SELECT
1
Configure Ghost Parameters
2
Partitions Backup, Mode LOCAL
3
Partitions Restore, Mode LOCAL
4
Delete Image
9
Back to previous Menu
Your Choice [1,2,3,4,9]?
Ghost Connection Mode:
LOCAL
Maximum Backup Images:
<max. Anzahl>
Actual Backup Images:
<akt. Anzahl>
the menu option Configure GHOST Parameters using key “1”.
Following menu:
PLEASE SELECT
1
Change Maximum Backup Images
9
Back to previous Menu
Your Choice [1,9]?
Choose the menu item Change Maximum Backup Images using key “1”.
Type the new number in the following menu and confirm the question: “Save
GHOST parameters” with “Yes”.
Storing a partition
backup
15 SW Installation/Update and Data Backup
Содержание SINUMERIK 840Di
Страница 1: ...Manual 06 2003 Edition SINUMERIK 840Di ...
Страница 2: ......
Страница 522: ...06 03 A 522 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition A Abbreviations Notes ...
Страница 548: ...06 03 Index 548 Siemens AG 2003 All rights reserved SINUMERIK 840Di Manual HBI 06 03 Edition Index ...
Страница 550: ......