NC Commissioning with HMI Advanced
11.7 Digital and analog I/O devices
Manual
468
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
11.7.1
Parameterization of the number of inputs/outputs used
Maximum number
The maximum number of digital or analog inputs/outputs that can be used for the NC is:
Total
MCI board extension
PROFIBUS modules
Analog inputs
8
-
8
Analog outputs
8
-
8
Digital inputs
36
4
32
Digital outputs
36
4
32
Note
The first digital input and output byte is permanently assigned to the MCI board extension
module (option). Therefore you can connect a maximum of 4 additional input/output bytes to
the PROFIBUS DP via signal modules. See configuration example Subsection
"Configuration example" (Page 473).
Machine data
The number of used analog and digital inputs/outputs is set in the following machine data
parameters:
Analog I/Os
●
MD10300 $MN_FASTIO_ANA_NUM_INPUTS ("number of active analog NC inputs")
●
MD10310 $MN_FASTIO_ANA_NUM_OUTPUTS ("number of active analog NC outputs")
Digital inputs/outputs
●
MD10350 $MN_FASTIO_DIG_NUM_INPUTS ("number of active digital NC input bytes")
●
MD10360 $MN_FASTIO_DIG_NUM_OUTPUTS ("number of active digital NC output
bytes")
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...