11.4 Memory configuration
Manual
382
Commissioning Manual, 05/2008, 6FC5397–4CP10–4BA0
11.4.1
DRAM memory
Free memory
The free DRAM memory is displayed via the following machine data:
●
MD18050 $MN_INFO_FREE_MEM_DYNAMIC (free dynamic memory)
The free DRAM should not be less than 15,000 bytes.
CAUTION
Before you enlarge DRAM areas, you should first check whether the free memory is
sufficient:
•
MD18050 $MN_INFO_FREE_MEM_DYNAMIC (free dynamic memory)
If more dynamic memory is requested than is available, the SRAM and therefore all user
data will be cleared without prior warning on the next NC startup!
To avoid data loss, a series startup file should be created before reconfiguration (see
Section "Creating a Series Startup File" (Page 543)).
Machine data
Table 11-12 Machine data required to configure the DRAM
Number
Name
Name/remarks
General ($MN_ ... )
18050
INFO_FREE_MEM_DYNAMIC
Display data of the free dynamic memory
18170
MM_NUM_MAX_FUNC_NAMES
Number of miscellaneous functions
18180
MM_NUM_MAX_FUNC_PARAM
Number of additional parameters
18210
MM_USER_MEM_DYNAMIC
User memory in DRAM
18240
MM_LUD_HASH_TABLE_SIZE
Hash table size for user variables
18242
MM_MAX_SIZE_OF_LUD_VALUE
Maximum field size of the LUD variables
18250
MM_CHAN_HASH_TABLE_SIZE
Hash table size for channel-specific data
18260
MM_NCK_HASH_TABLE_SIZE
Hash table size for global data
18340
MM_NUM_CEC_NAMES
Number of LEC tables
18342
MM_CEC_MAX_POINTS
Max. table size for sag compensation
18500
MM_EXTCOM_TASK_STACK_SIZE
Stack size for external communication task
18510
MM_SERVO_TASK_STACK_SIZE
Stack size of servo task
18520
MM_DRIVE_TASK_STACK_SIZE
Stack size of drive task
Channelspecific ($MC_ ... )
20096
T_M_ADDRESS_EXIT_SPINO
Spindle number as address extension
27900
REORG_LOG_LIMIT
Percentage of IPO buffer for log file enable
28000
MM_REORG_LOG_FILE_MEM
Memory size for REORG
28010
MM_NUM_REORG_LUD_MODULES
Number of modules for local user variables with REORG
28020
MM_NUM_LUD_NAMES_TOTAL
Number of local user variables
28040
MM_LUD_VALUES_MEM
Memory size for local user variables
Содержание SINUMERIK 840Di sl
Страница 118: ...Configuration 3 3 Connection overview Manual 118 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 148: ...Power On and Power Up 5 7 License management Manual 148 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 186: ...PLC commissioning 6 8 Load configuration in PG PLC STEP 7 Manual 186 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 344: ...Drive commissioning SINAMICS 9 5 Basic principles Manual 344 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...
Страница 624: ...Glossary Manual 624 Commissioning Manual 05 2008 6FC5397 4CP10 4BA0 ...