Ethernet communication
7
7.1
General information
7.1.1
Ethernet connections of the PCU 50.3
3&8
(WKHUQHW
6\VWHP1HWZRUN
(WKHUQHW
&RPSDQ\1HWZRUN
Figure 7-1
Ethernet connections of the PCU 50.3
The PCU 50.3 has 2 Ethernet connections (10/100 MBaud):
●
Ethernet 1 (company network)
●
Ethernet 2 (system network)
The interface: "Ethernet 1" is preset as a SINUMERIK DHCP client for connecting to a
company network or a PTP connection.
Ethernet 1
The interface: "Ethernet 2" is preset as a SINUMERIK DHCP server for connecting to a
system network with IP address 192.168.214.241.
Ethernet 2
The Ethernet components described below, e.g. Machine control panel MCP 483C IE, are
connected via this Ethernet interface.