3 Setting up functions
08/2008
3.2 Configuring measurements and measurement series
© Siemens AG 2008 All Rights Reserved
3-90
ePS Network Services, Function Manual (FH) - Release 08/2008
3.2.2 Synchronous operation axis test
Parameter description
Parameters for conducting a synchronous operation axis test:
Field Content
Type
Name
Name of the measurement series (measure-
ments do not have a name).
INPUT
Channel
Selection of the required channel. The chan-
nel defines the possible machine axes in the
"Axis" selection list.
SELECTION
Axis
Selection of the possible machine axes that
can be programmed in the selected channel.
SELECTION
Start point
The axis position at which the first partial
movement of the measurement begins.
INPUT
End point
The axis position at which the first partial
movement of the measurement ends.
INPUT
Feed
Velocity at which the axis is moved.
INPUT
Fig. 3-10: Synchronous operation axis test on the operator panel