Field Content
Type
Note:
The machine operator at the operator
panel can only view documents in PDF
format.
Security note on displaying PDF documents
Notice
PDF documents to be displayed on the control operator panel must not contain
any active contents (Java script, e-mail fields, etc.) nor have any HTML Links!
Otherwise there is a danger that it may be possible to navigate from the ePS
system to other Web pages.
ePS Network Services can display PDF documents compatible with Acrobat 1.3
(Reader Version 4.x) on the control operator panel.
For optimum display, please create your PDF documents with the option "Initial
View: Page Only/Magnification Fit Width".
3.1.2 Configuring variable monitors
Overview
You configure a variable monitor in the following steps:
1. Select the variable monitor or create a new variable monitor.
2. Name the variable monitor; comments and icons can be added as an option.
3. Define the PLC variables.
4. Use a control monitor to execute the variable monitor.
Selecting or creating variable monitors
Since it is possible for each machine to have several variable monitors, there is the
option of sorting them in the overview display either by their names or by the two
classification fields. In addition, it is possible to filter them by searching for specific
parts of text that appear in the Name and Variables columns using the "Search
text" box.