3 Setting up functions
3.3 Fault services
© Siemens AG 2008 All Rights Reserved
ePS Network Services, Function Manual (FH) - Release 08/2008
3-117
Fig. 3-24: Trigger on measurement series reaches limit value
Field Content
Type
Name
Designation for the trigger; can be
entered by the user. If the field re-
mains empty, or the designation is
deleted, ePS Network Services will
generate a designation from the se-
lected measurement ranges. A
consecutive number (n) can be added
to this.
DISPLAY
INPUT
(Max. 40 charac-
ters; any charac-
ter permissible)
Initiate trigger…
Select type of limit value
•
If at least one critical limit has been
exceeded
•
If at least one warning limit has
been exceeded (in which case the
critical limit may also have been
exceeded)
•
If only the warning limit has been
exceeded and the critical limit has
not yet been reached
SELECTION
1 of 3
Measurement se-
ries
1-n of n
Display and selection of the existing
measurement series for the trigger
DISPLAY
SELECTION
3.3.11 Server trigger on "Maintenance jobs due"
Description of functions
In order to monitor the execution of maintenance procedures by acknowledging
maintenance jobs, this trigger can be used to respond on a specific basis to one or
several jobs with time delays that can be configured differently. A notification is
available as a response.