4.9
Control Unit CU320-2 PN and CU310-2 PN
4.9.1
CU320-2 PN status displays
Module status displays
Three LEDs at the front of the CU320-2 PN provide information about the state of the module.
They indicate the states when powering up and in operation:
● If an error occurs, the power-up is terminated and the LEDs indicate the cause of the error.
● At the end of an error-free power-up, all LEDs are switched off briefly.
● After power-up, the LEDs are controlled via the loaded software.
Response of the LEDs when powering up – loading software
LED
State
Remark
RDY
PN
OPT
Red
Orange
Orange
Reset
Hardware reset
RDY LED lights up red, all other LEDs light
up orange
Red
Red
Off
BIOS loaded
–
Red flash‐
ing light 2
Hz
Red
Off
BIOS error
● An error occurred while loading the
BIOS
Red flash‐
ing light 2
Hz
Red
Flashing
light 2 Hz
Off
File error
● Memory card not inserted or faulty
● Software on memory card not present
or corrupted
Red
Orange
flashing
light
Off
FW loading
RDY LED lights up red, PN LED flashes
orange without fixed frequency
Red
Off
Off
FW loaded
–
Off
Red
Off
FW checked
(no CRC error)
–
Red flash‐
ing light 0.5
Hz
Red flash‐
ing light 0.5
Hz
Off
FW checked
(CRC error)
● CRC error
Response of the LEDs when powering up – firmware
LED
State
Remark
RDY
PN
OPT
Orange
Off
Off
Initializing
–
Alternating
Running
See the table below
Service cases - hardware
4.9 Control Unit CU320-2 PN and CU310-2 PN
Software and hardware
124
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
Содержание SINUMERIK 828D Turning