4.6
I/O modules
4.6.1
Status displays PP 72/48D PN
LEDs for status display
The following LEDs on the I/O module provide information about the module state:
Figure 4-18
Switch S1 and LEDs H1 to H6
H1 (green)
PowerOK
H2 (green)
PN Sync
H3 (red)
PN Fault
H4 (green)
Diag1
H5 (green)
Diag2
H6
OVTemp
Power OFF
OFF
OFF
OFF
OFF
OFF
OFF
Power ON (voltage is stable)
ON
OFF
OFF
OFF
OFF
OFF
Boot software runs and loads the system soft‐
ware.
ON
ON
ON
ON
ON
OFF
System software starts
ON
OFF
OFF
OFF
OFF
OFF
System software runs, no communication to the
controller.
ON
OFF
OFF
OFF
OFF
OFF
System software runs, communication to the
controller, STOP state
ON
ON
OFF
OFF
OFF
OFF
System software runs, communication to the
controller, RUN state
ON
Flashes at
0.5 Hz
OFF
OFF
OFF
OFF
Overtemperature alarm
--
--
--
--
--
ON