A2: Various NC/PLC interface signals and functions
1.3 Functions
Basic Functions
56
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
REFRESH suppression
MD10131 $MN_SUPPRESS_SCREEN_REFRESH (screen refresh in case of overload)
Default setting for screen-refresh strategy with high NC utilization:
• Value 0: Refresh of current values is suppressed in all channels.
• Value 1: Refresh of current values is suppressed in time-critical channels.
• Value 2: Refresh of current values is never suppressed.
1.3.2
Settings for involute interpolation - only 840D sl
Introduction
The involute of the circle is a curve traced out from the end point on a "piece of string" unwinding from the curve.
Involute interpolation allows trajectories along an involute.
Figure 1-6
Involute (unwound from base circle)
Programming
A general description of how to program involute interpolation can be found in:
5
;<
;
<
)
)
;
<
6WDUWSRLQW
(QGSRLQW
%DVHFLUFOHFHQWHU
%DVHFLUFOH
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...