F1: Travel to fixed stop
6.2 General functionality
Basic Functions
312
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
FOC fully automatically in REPOS
The
FOC-REPOS
function behaves analogously to the
FXS-REPOS
function.
Example:
A program moves axis X from 0 to 100 and activates
FOC
every 20 millimeters for 10 millimeters at a time. This
torque characteristic is generated with nonmodal
FOC
and therefore cannot be traced by
FOC-REPOS
.
FOC-
REPOS
will traverse axis X from 0 to 100 with or without
FOC
.
For programming examples of
FXS
"travel to fixed stop," please see:
References:
/FB1/ Function Manual Basic Functions; Mode Group, Channel, Program Operation (K1);
Section: Program test
6.2.4
Miscellaneous
Setting data
The following axisspecific setting data are provided for the "Travel to fixed stop" function:
SD43500 $SA_FIXED_STOP_SWITCH (selection of travel to fixed stop)
SD43510 $SA_FIXED_STOP_TORQUE (clamping torque for travel to fixed stop)
SD43520 $SA_FIXED_STOP_WINDOW (fixed stop monitoring window)
The setting data are effective only when the axis has reached the fixed stop.
The status of the setting data is displayed via the operator panel front in the "Parameters" area.
The commands
FXS[x]
,
FXST[x]
and
FXSW[x]
effect a block synchronous change in these setting data.
If
FXST[x]
and
FXSW[x]
are not programmed, then, if "Travel to fixed stop" is activated, the defaults from the
following machine data is copied to the corresponding setting data:
MD37010 $MA_FIXED_STOP_TORQUE_DEF (default for fixed stop clamping torque)
MD37020 $MA_FIXED_STOP_WINDOW_DEF (default for fixed stop monitoring window)
The setting data for clamping torque and fixed stop monitoring window can be changed by the operator and via
the PLC. It is thus possible to specify a higher or lower clamping torque or a modified fixed stop monitoring
window after the fixed stop has been reached.
Changing the clamping torque using the ramp and values greater than 100%
A clamping torque change is transferred to the drive steplike. It is possible to specify a ramp to always ensure
that a modified torque limit is reached: The setting is done via the following machine data:
MD37012 $MA_FIXED_STOP_TORQUE_RAMP_TIME
Note
A continuously changing torque characteristic cannot be implemented with
FOC-REPOS
.
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...