Parameter assignment
Maximum path length
The maximum distance up to which a block is still compressed, is set using machine data:
MD20170 $MC_COMPRESS_BLOCK_PATH_LIMIT
Longer blocks are not compressed, but are traversed normally.
Recommended setting: 20 [mm]
Maximum deviation of the path feedrate FLIN and FCUB
The maximum permissible deviation of the path feedrate for active compressor function COMPON or
COMPCURV is specified in the machine data in conjunction with FLIN and FCUB:
MD20172 $MC_COMPRESS_VELO_TOL
The higher the permissible deviation, the more short blocks that can be compressed into a long block.
Recommended setting: 100 [mm/min]
Axial deviation
For each axis involved in the compression, a maximum tolerable deviation of the generated path from the
program points can be specified. The setting is done on an axis-for-axis basis using the machine data:
MD33100 $MA_COMPRESS_POS_TOL
The higher the permissible deviation, the more short blocks that can be compressed into a long block.
Recommended setting: 0.01 [mm]
Contour accuracy
The maximum tolerable deviation of the generated path from the programmed points is specified using the
following setting data for each channel:
SD42475 $SC_COMPRESS_CONTUR_TOL
Compression mode
The manner in which the maximum tolerable deviation from MD33100 and SD42475 is taken into account is set
via the units position in the machine data:
MD20482 $MC_COMPRESSOR_MODE (mode of compression)
Value
Meaning
xx0
The tolerances specified with MD33100 $MA_COMPRESS_POS_TOL are maintained
for all the axes (geo and orientation axes).
xx1
The tolerances specified with SD42475 $SC_COMPRESS_CONTUR_TOL are
maintained for the geometry axes.
The tolerances specified with MD33100 $MA_COMPRESS_POS_TOL are maintained
for the orientation axes.
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...