Z1: NC/PLC interface signals
19.1 Various interface signals and functions (A2)
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
1619
DB19
DBX14.0 - DBX14.6 PLC index
Edge evaluation: No
Signal(s) updated: Cyclic
Description
This byte for control of the V24 interface describes the PLC index for the standard control file, which
specifies the axis, channel or TO number. This file is handled according to the contract from the
PLC → HMI in the interface signal:
DB19 DBB12
Application
example(s)
Valid for HMI Embedded, with reference to DB19 DBB12
Dependent on:
DB19 DBX14.7=0 → Akt. FS: PLC index that specifies axis, channel or TO No.
DB19 DBX14.7=1 → Pas.FS: PLC index for the user control file
DB19
DBX14.7
Active or passive file system
Edge evaluation: No
Signal(s) updated: Cyclic
Signal state 1 or
edge change 0 → 1
Passive file system
Signal state 0 or
edge change 1 → 0
Active file system
Application
example(s)
Valid for HMI Embedded, with reference to DB19 DBB12
DB19
DBB15
PLC line offset
Edge evaluation: No
Signal(s) updated: Cyclic
Description
This byte to control the RS-232-C interface defines the line of the standard or user control file in
which the control file to be transferred is specified.
Application
example(s)
Valid for HMI Embedded, with reference to DB19 DBB12
Dependent on:
DB19 DBX14.7=0 → Akt. FS: PLC line offset in a standard control file
DB19 DBX14.7=1 → Pas. FS: PLC line offset in a user control file
DB19
DBX16.0 - DBX16.6 PLC index for the user control file
Edge evaluation: No
Signal(s) updated: Cyclic
Description
This byte for controlling file transfer via hard disk defines the index for the control file (job list). This
file is handled from the PLC → HMI corresponding to the contract which is in DB19 DBB13.
Application
example(s)
Valid for HMI advanced, with reference to the interface signal:
DB19 DBB13
Dependent on:
DB19 DBX14.7=0 → Akt. FS: PLC index for the standard control file
DB19 DBX14.7=1 → Pas.FS: PLC index for the user control file
DB19
DBX16.7
Active or passive file system
Edge evaluation: No
Signal(s) updated: Cyclic
Signal state 1 or
edge change 0 → 1
Passive file system
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...