14.4.2.3
Restrictions
The advantage of displaying the status in the program editor is due to the fact that you obtain a graphic display of
the events in your program. However, not all of the tools are available as in the status chart (e.g. the function
"Single read", "Write all").
It is important that you know the restrictions of the program status if you test and monitor your program.
Signal flow
The color marking for "Signal flow" does not mean that there is always a signal flow!
In the program status in LAD, the values are only displayed at the end of the cycle. This means that it can be
sometimes difficult to evaluate just what the "signal flow" display really means. Boolean contacts and coils are
shown color coded in the program status in LAD corresponding to the value of the bit addresses. If the bit value
is 1 (bit is enabled), then the operation is marked in color. However, this does not necessarily mean that the
operation was actually executed. There are several conditions that can result in an unclear signal flow display:
• If, when evaluating the status, the target system is in the STOP operating state, contacts can be activated,
however, coils and boxes are not switched-on because the program is not being executed.
• If the program contains a jump operation, then it is possible that the networks that you are investigating, do
not display the expected results because the target system skipped these operations while executing the
program.
• It is a similar situation if you consider a subprogram. The boolean addresses can be activated, however, the
subprogram logic can only be executed if the subprogram is activated. If the subprogram was not called from
the main program, then no logic of the networks was executed regardless of what the bit values of the
operations display.
Status at the end of the cycle in LAD
If you display the program status in the program editor in LAD, the status is updated at the end of every cycle.
Displaying your program in another programming language has no effects at all on the actual program.
14.4.2.4
Adapting the program status display
Adapting the program status display in the program editor
Procedure:
1. Select the menu command "Tools > Options".
2. Open the "Status" tab.
You can now edit the following settings:
Содержание SINUMERIK 828D Turning
Страница 34: ...Basic Functions 34 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 146: ...A3 Axis Monitoring Protection Zones 2 6 Data lists Basic Functions 146 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 328: ...F1 Travel to fixed stop 6 5 Data lists Basic Functions 328 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 816: ...K2 Axis Types Coordinate Systems Frames 10 9 Data lists Basic Functions 816 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1198: ...P4 PLC for SINUMERIK 828D 14 6 Function interface Basic Functions 1198 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1752: ...Appendix 20 2 Overview Basic Functions 1752 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...
Страница 1774: ...Glossary Basic Functions 1774 Function Manual 09 2011 6FC5397 0BP40 2BA0 ...