6.5.3
Technical data
Note
An open input is interpreted as "low".
Note
Terminals MEXT1 ... MEXT4 must be connected for the digital inputs/outputs to function. This
can be done as follows:
● Connect the ground reference of the digital inputs.
● A jumper to terminal M on plug connector X1.
P24EXT (P1, P3) must also be connected so that the outputs function. An external supply
can also be connected here, or a jumper can be inserted to terminal P at X1.
This removes the galvanic isolation for these digital inputs.
Digital inputs
Table 6-6
Technical data of the digital inputs at X122/X132 and X242/X252
Parameter
Value
Voltage
-3 V to 30 V
Typical power consumption
10 mA at 24 V DC
Signal level (including ripple)
High: 15 V to 30 V
Low: -3 V to 5 V
Signal propagation times
L → H: 50 μs
H → L: 150 μs
Galvanic isolation
Yes:
The reference potential is terminal 2M at X122/X132.
The reference potential is terminal 4M at X242/X252.
Digital inputs/outputs
Table 6-7
Technical data of the digital inputs/outputs at X122/X132
Parameter
Value
As input:
Voltage
-3 V to 30 V
Typical power consumption
10 mA at 24 V DC
Signal level (including ripple)
High: 15 V to 30 V
Low: -3 V to 5 V
Signal propagation (rapid inputs)
L → H: 10 μs
H → L: 150 μs
Galvanic isolation
Yes: The reference potential is terminal 1M.
Interface description
6.5 Digital inputs/outputs
PPU
Manual, 01/2014, 6FC5397-2DP40-3BA3
83