Technical specifications
4.1 Radio interference
Electrical Installation Manual
42
Operating Instructions, 12/2014, 6FC5397-2EP10-0BA0
PPU
MCP
Shock resistance (in operation)
10 g peak value, 6 ms duration
6 shocks in each of the 3 axes vertical to each other
Lithium battery
Rated output voltage
3 V
-
Maximum capacity
950 mAh
-
Life time
3 years
-
Certificate
CE
CE
4.1
Radio interference
Table 4- 1
Limit values for radio interference suppression in industrial environments
Limit class according to EN61800-3
Conducted radio interference
C3
Radio interference
C3
Note
You must consider interference radiation for the complete system. Particular attention should
be paid to cabling. Contact your sales representative for assistance and support.
If compliance with limit value class C2 is required, contact your local Siemens sales partner.