Connecting
3.3 Connecting the interfaces on the PPU
Electrical Installation Manual
24
Operating Instructions, 12/2014, 6FC5397-2EP10-0BA0
Connection cables
End sleeves are necessary if you use two cables per connection.
Fasten the cables to the screw terminals and plug the terminal into the interface X21.
You can buy the shielded cables from a third-party manufacturer.
3.3.4
Distributed I/O - X301, X302
Pin assignment
Type
50-pin socket
Inputs
Permissible level (including ripple)
High level: 18 V - 30 V
Low level: -3 V - +5 V
Outputs
Rated digital output current: 250 mA